earth icon
  • Select Language

GX560
21.3" Monochrome LCD Monitor
5 megapixel monochrome monitor with a thin bezel design for comfortable breast image viewing.

Making Each Life Visual


 

Evolve Your Image Reading

The GX560 MammoDuo integrates two GX560 monitors side by side on a specifically designed stand.

RadiForce GX560 MammoDuo
 

Distraction-Free Viewing

With a 7.5 mm bezel, the world's narrowest bezel on a 5 megapixel monitor, the total distance between two side-by-side screens is only 15 mm. Furthermore the screen is almost completely flat with the bezel sitting only 2.5 mm above the screen.
Distraction-Free Viewing

 

Space Saving

Due to the thinner bezels, the GX560 MammoDuo is slimmer than two conventional 5 megapixel monitors by 67 mm horizontally, 36 mm vertically and 20.5 mm in depth. Furthermore, the total occupying space is reduced by 22%.

Space Saving1

Space Saving

 

Easy Adjustment

With the newly designed stand, you can adjust the height, tilt, and swivel of the two monitors without any gaps appearing between them.
 

Easy Adjustment_topdownEasy Adjustment_swivel



Ribbon
 

The RadiForce GX560 is also available as a single monitor and stand.



 

Evolve Your Image Reading

Work-and-Flow_logo.jpg

As more image modalities become digitalized, radiologists are viewing an increasing amount of information on their screens. EIZO's unique Work-and-Flow technology alleviates the complexity of the imaging workflow with new functions developed with the radiologist in mind. Users can take advantage of Work-and-Flow functions with the RadiForce monitor and bundled RadiCS LE software.

 

Barrier-Free Workstyle

With the Switch-and-Go function, you can operate two different workstations at the same time with a single mouse and keyboard. Work across several monitors by moving the cursor from one screen to the other or switch the signals between workstations as needed without having to change your mouse or keyboard each time. This makes it possible to reduce the number of monitors in the workflow and improves work efficiency.
 

Switch-and-Go_GX560_en.jpg

See more with animation gif_animation_icon


 

Quick and Easy Focus

With the Point-and-Focus function, you can quickly select and focus areas of your concern with just your mouse and keyboard. Change the brightness and grayscale tones of certain points on the screen to make interpretation easier.
 

Point-and-Focus_GX560_en.jpg  

See more with animation gif_animation_icon

 

 

 

View Mammography Images Clearly

5 megapixel monitors allow you to see smaller details that are essential in digital mammography. The high resolution retains important information to prevent decreased image quality and pixelation that occurs when viewing at a lower resolution.

View Mammography Images Clearly

 

 

Optimum Breast Screening Monitor

The GX560 adopts an LTPS (Low Temperature Polysilicon) panel, which allows the monitor to achieve a maximum brightness of 2,500 cd/m2. If calibrated to the recommended brightness of 1000 cd/m2, EIZO guarantees 5 years of use.

Furthermore, it has a contrast ratio of 1700:1, displaying deep blacks and bright whites without any washout. This makes it suitable to use with breast tomosynthesis and mammography which require clear visibility.
 

The monitor has obtained FDA 510(k) clearance by the U.S. Food and Drug Administration for breast tomosynthesis and mammography. This ensures that the monitor is capable of displaying detailed breast screening images where high performance is essential.

PinkRibbon

Optimum Breast Screening Monitor


 

High Definition Display with Smooth Transition

The monitor has a response time of 12 milliseconds, making it ideal for smoothly and continuously viewing tomographic images such as breast tomosynthesis, MRI and CT. In addition, with a pixel pitch of 0.165 mm and 10-bit (1,024 tones) simultaneous grayscale display, subtle density differences can be easily distinguished.

 

Achieve Clarity True to the Source Data

A medical monitor needs to be capable of high brightness in order to meet performance standards. However, in order to achieve high brightness in an LCD panel, the pixel aperture ratio has to be increased. This causes a typically unavoidable decline in sharpness. With EIZO's unique Sharpness Recovery technology, the decrease in sharpness (MTF) is restored. This allows you to display an image safely on the monitor that is true to the original source data, even at high brightness levels.

MTF measures numerically how faithfully the panel transfers detail from the original image data for viewing. When Sharpness Recovery is turned on, in the case of a 2 pixel line pair (spatial frequency of 1.515 cycles/mm) the MTF increases by approximately 45.5%.
Sharpness Recovery

 

Variations for Specific User Needs

EIZO offers anti-glare (AG) and anti-reflection (AR) screen variations to suit user environments. AG treatment is ideal for exceptionally bright environments and drastically reduces glare from ambient lighting. AR treatment is ideal for moderately-lit environments to reduce mild screen glare while maintaining crisp text and images.

Read more about AR treatment [PDF]

Variations for Specific User Needs

 

 

Hassle-Free Multi-Monitor Configuration

Using the DisplayPort connection, you can drive several monitors in a daisy chain sequence. This allows you to configure a multi-monitor setup without the complicated hassle of excessive cabling.

A graphics board that supports daisy chain is necessary.
Hassle-Free Multi-Monitor Configuration



 

Make the Precise Diagnosis

EIZO carefully measures and sets each grayscale tone to create a monitor compliant with DICOM Part 14. Furthermore, at startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level and compensates the brightness fluctuations caused by the ambient temperature and the passage of time, allowing medical images to be faithfully reproduced with stable brightness and grayscale.

Make the Precise Diagnosis


 

Manage Effortless Quality Control

With the RadiCS LE software (included) and Integrated Front Sensor (IFS) built into the front bezel, you can easily calibrate to DICOM Part 14 without having to mount, run, and remove an external sensor.

Simple calibration using the monitor backlight sensor is also supported.

DICOM Part 14

Integrated Front Sensor


 

Select the Ideal Mode for Modalities

The CAL Switch function allows you to choose various modes for different modalities such as mammography, MRI, and endoscopy. It can be conveniently accessed using the monitor's front panel buttons to easily switch to optimal image viewing conditions.
 

Conserve Energy While Away

A presence sensor prompts the monitor to switch to power save mode when the user is away and resumes operation upon their return to conserve power when not in use, uniting convenience with savings.

Conserve Energy While Away


 

Digital Mammography Monitor Quality Control Standards Compliance

EIZO's easy-to-use RadiCS UX2 quality control software & calibration sensor (sold separately) performs precise calibration conforming to DICOM Part 14 and enables quality control complying with ACR Practice Guideline and other QC standard for digital mammography monitors.



 

Rest Assured with Medical Qualifications

The monitor meets the strictest medical, safety, and EMC emission standards.

Rest Assured with Medical Qualifications

Warranty with Safety and Trust

EIZO and its authorized distributors offer a five-year full warranty.

 

 

Our Contribution to SDGs

As part of its sustainability initiatives, EIZO is contributing towards the United Nations' Sustainable Development Goals (SDGs). 
SDGs Logo

Supporting a Healthy Life
Starting with our message “Making Each Life Visual”, we aim to support optimal medical care for each and every individual through accurate diagnosis and treatment afforded by our innovative healthcare technologies.
 

SDGs 03SDGs 08
 
 
 
Environmentally Conscious
Our healthcare products are designed to promote energy efficiency for reduced power consumption and greenhouse gas emissions, while maintaining the high performance and functionality needed in healthcare. We also implement a responsible after-service recycling system.
 

SDGs 07SDGs 12


Model VariationsGX560-BK-MD: Anti-Glare coating, two screens, with dual stand, black
GX560-ARBK-MD: Anti-Reflection coating, two screens, with dual stand, black
GX560-BK: Anti-Glare coating, one screen, with stand, black
GX560-ARBK: Anti-Reflection coating, one screen, with stand, black
Panel 
TypeMonochrome (IPS)
BacklightLED
Size21.3" (54.1 cm)
Native Resolution2048 x 2560 (4:5 aspect ratio)
Viewable Image Size (H x V)337.9 x 422.4 mm
Pixel Pitch (H x V)0.165 x 0.165 mm
Grayscale Tones10-bit (DisplayPort): 1,024 from a palette of 16,369 (14-bit) tones
8-bit: 256 from a palette of 16,369 (14-bit) tones
Viewing Angles (H / V, typical)178° / 178°
Brightness (typical)2500 cd/m2
Recommended Brightness for Calibration1000 cd/m2, 600 cd/m2
Contrast Ratio (typical)1700:1
Response Time (typical)12 ms (black-white-black)
Video Signals 
Input TerminalsDisplayPort x 2, DVI-D (dual link)
Output TerminalsDisplayPort (daisy chain)
Digital Scanning Frequency (H / V)31 - 135 kHz / 23 - 61 Hz
USB 
UpstreamUSB 2.0: Type-B x 2
DownstreamUSB 2.0: Type-A x 2
Power 
Power InputAC 100 - 240 V: 50 / 60 Hz
Typical Power Consumption28 W
Maximum Power Consumption79 W
Power Save Mode1 W or less
SensorBacklight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor
Features & Functions 
Brightness StabilizationYes
Digital Uniformity EqualizerYes
Work-and-FlowSwitch-and-Go, Point-and-Focus
Preset ModesCAL Switch (DICOM, CAL1, CAL2, Text)
OSD LanguagesEnglish, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Physical Specifications 
Net WeightGX560-MD, GX560-AR-MD:
17.1 kg

GX560, GX560-AR:
8 kg
Net Weight (Without Stand)5.2 kg
Hole Spacing (VESA Standard)100 x 100 mm
Certifications & Standards (Please contact EIZO for the latest information.)GX560, GX560-AR:
CE / UKCA (Medical Device), ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1, IEC/EN60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA510(k) Clearance for Breast Tomosynthesis, Mammography, and General Radiography
Dedicated Software 
Monitor Quality Control Software RadiCSSupported
Supplied Accessories (May vary by country. Please contact EIZO for details.) 
Signal CablesGX560-MD, GX560-AR-MD:
DisplayPort (3 m) x 4, DisplayPort (1 m)

GX560, GX560-AR:
DisplayPort (3 m) x 2
OthersGX560-MD, GX560-AR-MD:
AC power cord (3 m) x 2, USB Type-A - USB Type-B cable (3 m) x 4, Utility Disk (RadiCS LE, PDF installation manual), instructions for use

GX560, GX560-AR:
AC power cord (3 m), USB Type-A - USB Type-B cable (3 m) x 2, Utility Disk (RadiCS LE, PDF installation manual), instructions for use
Warranty5 Years
Dimension DrawingPDF


Brochures

RadiForce general
14.4 MB

Download






Graphics Boards

MED-XN83

- EIZO original driver and bios
- Daisy chain supported

Recommended
MED-XN63

- EIZO original driver and bios
- Daisy chain supported

MED-XN43

- EIZO original driver and bios
- Daisy chain supported

MED-XN51LP

- EIZO original driver and bios
- Daisy chain supported

MED-XN31LP

- EIZO original driver and bios
- Daisy chain supported

MED-XN72

- EIZO original driver and bios
- Daisy chain supported













Quality Control Software & Tools

RadiCS UX2

- Quality Control Software
- UX2 Calibration Sensor bundled

UX2 Sensor


- Quality Control External Calibration Sensor

Comfort Light for Reading Rooms

RadiLight

- Comfort Light for Reading Rooms